An AI-Native Energy Digital Twin

EnergySmart creates a virtual model of your chiller plant, AHUs, boilers, cooling towers, pumps, and distribution systems. The AI runs in real time against live sensor data, validates expected vs. actual performance, and surfaces where energy is being lost at asset, zone, and facility level.

The Losses Are Silent and Compounding

Low Delta-T syndrome, fouled heat exchangers, oversized pump flow, mis-sequenced chillers, and poorly reset supply air temperatures silently waste 20-35% of HVAC energy in a typical plant. Nobody notices because there is no calibrated baseline to compare against.

The Closed Optimisation Loop

EnergySmart does not just flag problems. It calculates the optimal operating point, pushes setpoint adjustments via aQ Core, and then measures actual energy change against the physics model. Every kWh saved is time-stamped and attributed.

AI-Native Platform

Ask Questions. Get Savings.

No dashboards to configure. No reports to build. Just tell the AI what you need to know about your energy performance and it delivers.

Your Energy Engineer, Always On.

EnergySmart is not a dashboard you check. It is an AI energy analyst that continuously monitors your HVAC plant, identifies inefficiencies, calculates savings opportunities, and explains exactly why something is happening in plain language.

The difference:

Traditional platforms show you charts. EnergySmart tells you "Chiller 2 is running at 0.72 kW/TR because the condenser water setpoint is 2°C too high adjusting now will save $4,200/month."

One command. The AI investigates, diagnoses, recommends, and acts. You verify the results.
testimonials
Autonomous Diagnostics

The AI continuously scans for inefficiencies, explains root causes, and calculates the financial impact without being asked.

Natural Language Analysis

Ask "why is Building C using more energy?" and get a physics-based explanation, not a chart to interpret.

Auto-Optimisation

When the AI identifies a setpoint improvement, it can push the change directly to the BMS via aQ Core closed loop.

Instant M&V Reports

Generate IPMVP-compliant verification reports with one command. No manual data pulling or spreadsheet work.

Savings Prioritisation

The AI ranks every optimisation opportunity by ROI, payback period, and implementation complexity automatically.

Predictive Forecasting

Ask "what will our energy cost be next month?" and get a forecast based on weather, occupancy, and tariff data.

The 6-Layer Optimisation Engine

AI-Driven HVAC/R Optimisation

Physics-based optimisation across every component of your HVAC plant.

01

Chiller Plant Efficiency

kW/TR Tracking & Chiller Sequencing

Real-time kW/TR against the physics-derived efficiency curve. Detects staging inefficiencies, part-load penalties, and compressor degradation. Best-in-class target: <0.7 kW/TR.

Chiller Sequencing

COP Tracking

ASHRAE GL36

02

Delta-T Correction

Low Delta-T Syndrome Elimination

EnergySmart tracks system ΔT continuously, identifies root causes (coil bypass, stuck valves), and drives corrective sequences to restore the target 5-8°C differential.

ΔT Monitoring

Root Cause Analysis

Valve Coordination

03

Pump Affinity Optimisation

VFD Speed vs. Affinity Law 49% Savings

Pump power scales with flow³. Reducing flow by 20% cuts pump power by nearly 50%. This single optimisation is typically the largest single energy saving in the plant.

VFD Control

ΔP Reset

Flow Optimisation

04

Cooling Tower Optimisation

Condenser Water vs. Fan Energy Trade-off

EnergySmart calculates the optimal CWS setpoint using wet-bulb tracking and coordinates tower fan VFDs to minimise combined chiller + tower energy.

Approach Temp

Fan VFD

Wet Bulb Tracking

05

AHU Optimisation

Supply Air Reset · DCV · Economiser · SFP

Supply air temperature reset, demand-controlled ventilation using CO₂, economiser free-cooling sequences, and fan speed optimisation targeting SFP <1.5 W/(l/s).

SAT Reset

DCV / CO₂

Economiser

06

Model Predictive Control (MPC)

Weather-Adaptive · Pre-cool · Peak Shaving

MPC runs predictive models using weather forecasts, occupancy schedules, and thermal mass data. Pre-conditions spaces during low-tariff periods.

Demand Response

Weather-Adaptive

Peak Shaving

The Validation Loop

Verified Savings, Not Claims

Most optimisation platforms show a dashboard of "potential savings." EnergySmart closes the loop: a physics-derived baseline is calibrated to actual plant data before any optimisation begins. Every kWh saved is verifiable against the IPMVP M&V baseline.

01

Baseline

Physics model calibrated to actual plant data

02

Detect

Deviation from baseline. Root cause isolated.

03

Optimise

Optimal operating point calculated and applied

04

Measure

Actual energy vs. prediction, timestamped

05

Verify

Savings attributed. IPMVP report generated.

Use Cases

Where EnergySmart Delivers Value

Commercial Office Buildings

Large central plants with chillers, cooling towers, and AHUs serving multiple floors and tenants.

  • Chiller sequencing optimisation
  • Tenant comfort with energy savings
  • Green lease compliance

Data Centers

Mission-critical cooling with stringent uptime requirements and massive energy footprints.

  • PUE reduction to <1.4
  • Hot aisle/cold aisle optimisation
  • Redundancy without waste

Manufacturing & Industrial

Process cooling, compressed air, and HVAC integration for production environments.

  • Process cooling efficiency
  • Peak demand management
  • Production schedule integration

Hotels & Hospitality

Guest comfort expectations combined with high energy costs and 24/7 operation.

  • Guest room temperature optimisation
  • Central plant right-sizing
  • Night setback strategies

Healthcare Facilities

Critical environments with strict temperature and humidity requirements for patient safety.

  • OR and pharmacy compliance
  • Redundancy optimisation
  • 24/7 critical monitoring

Retail & Shopping Centers

Large conditioned spaces with variable occupancy and tenant cost allocation needs.

  • Tenant sub-metering
  • Load shedding during peaks
  • After-hours setback

Industry Solutions

AI-Optimised for Your HVAC Configuration

Centrifugal Chillers

VFD staging, kW/TR tracking, condenser optimisation

Image

Screw Chillers

Part-load efficiency, compressor cycling optimisation

Image

Boiler Plants

Combustion efficiency, staging, condensing optimisation

Image

Heat Pumps

COP tracking, defrost optimisation, reversing valve control

Image

AHU Systems

SAT reset, economiser, DCV, SFP optimisation

Image

Cooling Towers

Approach temp, fan VFD, water treatment integration

Image

VFD Pumps

Affinity law optimisation, ΔP reset, staging

Image

VAV Systems

Zone pressure optimisation, reheat minimisation

Image

Platform Comparison

aQ EnergySmart vs. Other Smart Building Platforms

Capability Aqueduct (EnergySmart) Other Smart Building Platforms
AI-native architecture Built on AI from day one AI bolted on to legacy platform
Natural language diagnostics Ask why, get physics-based answer Charts only, interpretation required
Physics digital twin EnergyPlus-calibrated ML model only or partial physics
M&V baseline + verification IPMVP Option A/B Model-relative only
Auto-generated reports One command, instant M&V report Manual report building
Outcome-based pricing Linked to kWh saved Project or subscription pricing

Measurable Results

Proven Energy Outcomes

Upto - 30%

Energy Bill Reduction
Whole-facility savings

49%

Pump Energy Savings
Via affinity law optimisation

<0.7

kW/TR Chiller Target
Best-in-class efficiency

AI

Native Intelligence
Not bolted on

Ready to Prove Your Energy Savings?

  • Live AI demo
  • Custom ROI projection
  • IPMVP methodology

See how EnergySmart delivers AI-verified 15-35% energy reduction with physics-based M&V.